What is the power rating of Cummins Onan QD 10000 10.0HDKCA-11506?
10 kW
The cited OEM source lists Rated power for Cummins Onan QD 10000 10.0HDKCA-11506 as 10 kW.
Cummins Onan QD 10000 10.0HDKCA-11506 — Rated power: 10 kW · Frequency: 60 Hz · Voltage: 120/240 V Sources, symptoms, measurements and verification on one page.
10 kW
The cited OEM source lists Rated power for Cummins Onan QD 10000 10.0HDKCA-11506 as 10 kW.
60 Hz
The cited OEM source lists Frequency for Cummins Onan QD 10000 10.0HDKCA-11506 as 60 Hz.
120/240 V
The cited OEM source lists Voltage for Cummins Onan QD 10000 10.0HDKCA-11506 as 120/240 V.
83.3 A
The cited OEM source lists Current at 120V for Cummins Onan QD 10000 10.0HDKCA-11506 as 83.3 A.
41.7 A
The cited OEM source lists Current at 240V for Cummins Onan QD 10000 10.0HDKCA-11506 as 41.7 A.
1
The cited OEM source lists Phase for Cummins Onan QD 10000 10.0HDKCA-11506 as 1.
10 kW
60 Hz
120/240 V
83.3 A
41.7 A
1
10 kW
60 Hz
120/240 V
QD 10000 10.0HDKCA-11506: OEM-published Rated power reference is 10 kW. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
QD 10000 10.0HDKCA-11506: OEM-published Frequency reference is 60 Hz. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
QD 10000 10.0HDKCA-11506: OEM-published Voltage reference is 120/240 V. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
QD 10000 10.0HDKCA-11506: OEM-published Current at 120V reference is 83.3 A. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
Output voltage/frequency instability or collapse under load
Low-oil/high-temperature shutdown or hard starting
J1939/remote-control communication issue
Compare output voltage, frequency, current and phase with the recorded rating; apply load-bank steps without exceeding the nameplate.
On variable-speed models, log rpm, inverter output, oil and temperature shutdown inputs at the event.
Separate engine-speed/governor faults from alternator/inverter output faults by correlating rpm with Hz/voltage deviation on the same time base.
Preserve self-diagnostic code, shutdown reason and actual load together.
Check voltage/frequency stability and shutdown recurrence at no-load, 25%, 50%, 75% and permitted full-load steps.
QD 10000: exact maintenance interval, fluid-change quantity and torque procedure must be verified from OEM maintenance/service information matched to model year/VIN/serial number; unpublished service thresholds are not invented in this record.
QD 10000: Evaluate engine/governor, alternator/inverter control and remote/J1939 interface together.
QD 10000: Output voltage/frequency/current measurement.
QD 10000: Engine speed / governor command.
QD 10000: Oil-pressure or low-oil shutdown input.
QD 10000: Engine-temperature shutdown input.
QD 10000: Alternator/inverter regulation data.
QD 10000: Remote/J1939 control state where fitted.
Only exact values published by the cited source are shown numerically. Pins, torque, pressure, resistance or service thresholds not publicly published are not invented; use the VIN/model-year/calibration-matched OEM service procedure.
Exact technical values, prices and failure rates are not invented without verified vehicle/manufacturer evidence.